10001 Brighton Rd.
Denver, CO 80640
Phone: (303) 287-0223
Toll Free: (800) 326-9989
Fax: (303) 287-6306
email: info@a-jsales.com
Pressure Washers
Water Heaters
Parts Washers
Steel Eagle
Pumps/ Accessories
Request Literature
Links
Email Us
Superior Trailers
About Us
Home |
|

|
|
Series 3000,5000,6000
Standard Features
-
ETL Listed
-
Heavy Duty Tubular Steel Frame
-
Heavy Duty Legs
-
Durable Hi-gloss Powder Coated Paint
-
Stainless Steel Compartment Covers
-
Stainless Steel Combustion Chamber
-
Heating Coil Constructed of ASTM A53 Schedule 80
-
Steel Pipe
-
Fuel Efficient Combustion Chamber
-
Adjustable Temperature Control
-
High-limit Temperature Control
-
Waterproof Ignition Transformer
-
Pressure Relief Valve
-
Belt Driven Pump
-
Trigger Gun Control
-
Stainless Steel Float Tank
-
Low Water Shut-off Protection
-
Wire Braid Discharge Hose
-
Quick Coupled Stainless Steel Nozzles
-
Automatic Shutdown Timer
-
Watertight Electrical Panel
-
Diagnostic Control Monitoring Lights
-
Calibrated Detergent Mixing Valve
-
Fuel Water Separator
-
Electronic Ignition
-
Hour Meter
-
Soap Solenoid
-
Cad Cell Flame Sensor (Oil fired units)
-
Draft Diverter
|

|
|

|
Control Panel
Easy to understand accessible controls make the AaLadin Pressure Washer simple and safe to operate. The calibrated detergent mixing valve precisely meters detergent allowing for high-pressure soap application
|
Dual Pump Module
AaLadin's standard features are designed to promote longer life. Quality features such as the belt driving the pump enhance trouble free operation by isolating heat and vibration from the pump and allowing for overload protection. The 6000 series pump module shown utilizes a dual pump configuration to minimize the possibility of down time from the possibility of pump failure |
 |
|

|
Draft Diverter
Protect your hot water machine from the updrafts that can extinguish the pilot light on gas machines and hinder proper venting of the exhaust with this draft diverter. It fits easily on top of the stack head and is standard equipment on all gas fired machines. |
Pump Module Access
Front panel opens and raises up out of the way for easy access to the pump and motor area. |
 |
|

|
Remote Control Station
The remote operation station allows the user the ability to operate the panel controls away from the unit. All remote control stations are 24 volts. |
Easy Burner Accessibility
End panel door opens allowing spacious easy access to burner and gas valve. |
 |
|

|
Heat
Chamber - AaLadin Exclusive
The AaLadin heating chamber construction
provides long life and fuel efficiencies unsurpassed in the industry.
Coils are made of high test ASTM A53 steel pipe wound on a spiral
helix with special hot gas baffling. We blanket insulate the entire
chamber with a highly efficient insulation blanket with low heat
storage and high heat reflectance.Our burner system has a worldwide
reputation for superior performance and reliability. |
ETL Listed
All models in standard configuration are ETL Listed to ensure safety and the capability of meeting electrical code requirements. (Steam Combination units not ETL Listed) |
|
|
3000
With 1600 to 3000 PSI high pressure, 300 PSI steam, and 3.0 to 5.0 GPM
these stationary pressure washers have exceptional power to get the
job done fast.
| Model |
 |
3303 |
 |
3416 |
 |
3423 |
 |
3430 |
 |
3518 |
 |
3523 |
 |
3530 |
| Flow
Output (GPM) |
|
3 |
|
4 |
|
4 |
|
4 |
|
5 |
|
5 |
|
5 |
| Pressure
Ratings (PSI) |
|
300 |
|
1600 |
|
2300 |
|
3000 |
|
1800 |
|
2300 |
|
3000 |
| Max
Output Temperature (°F) |
|
300° |
|
210° |
|
210° |
|
210° |
|
210° |
|
210° |
|
210° |
| Cleaning
Comparison Index (1) |
|
5812 |
|
15112 |
|
18118 |
|
20693 |
|
20036 |
|
22648 |
|
25866 |
| Motor
Horsepower |
|
.75 |
|
4 |
|
6 |
|
8/7.5 |
|
6 |
|
8/7.5 |
|
10 |
| Electrical
Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Volt |
|
115 |
|
230 |
|
230 |
|
230 |
|
230 |
|
230 |
|
230 |
| Amp |
|
10 |
|
20/15 |
|
20/15 |
|
30/25 |
|
30/20 |
|
30/25 |
|
30 |
| Phase |
|
1 |
|
1
or 3 |
|
1
or 3 |
|
1
or 3 |
|
1
or 3 |
|
1
or 3 |
|
3 |
| Oil
Fired Burner System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Input
BTU's |
|
420,000 |
|
350,000 |
|
350,000 |
|
350,000 |
|
420,000 |
|
420,000 |
|
420,000 |
| Fuel
Consumption (GPH) (2) |
|
1.8 |
|
1.5 |
|
1.5 |
|
1.5 |
|
1.8 |
|
1.8 |
|
1.8 |
| Burner
Fuel Tank Capacity |
|
15.5 |
|
15.5 |
|
15.5 |
|
15.5 |
|
15.5 |
|
15.5 |
|
15.5 |
| Stack
Size |
|
8" |
|
8" |
|
8" |
|
8" |
|
8" |
|
8" |
|
8" |
| Gas
Fired Burner System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Input
BTU's |
|
440,000 |
|
400,000 |
|
400,000 |
|
400,000 |
|
440,000 |
|
440,000 |
|
440,000 |
| Fuel
Consumption NG (CFH) (2) |
|
264 |
|
240 |
|
240 |
|
240 |
|
264 |
|
264 |
|
264 |
| Fuel
Consumption LP (LBH) (2) |
|
13.1 |
|
11.91 |
|
11.91 |
|
11.91 |
|
13.1 |
|
13.1 |
|
13.1 |
| LP
Tank Minimum Size |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
| Stack
Size |
|
10" |
|
10" |
|
10" |
|
10" |
|
10" |
|
10" |
|
10" |
| Discharge
Hose |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
| Approx.
Weight (lbs) |
|
730 |
|
728 |
|
776 |
|
794 |
|
824 |
|
848 |
|
848 |
| Dimensions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Length |
|
56" |
|
56" |
|
56" |
|
56" |
|
56" |
|
56" |
|
56" |
| Width |
|
24" |
|
24" |
|
24" |
|
24" |
|
24" |
|
24" |
|
24" |
| Height |
|
55" |
|
55" |
|
55" |
|
55" |
|
55" |
|
55" |
|
55" |
|
|
|
5000
For extra cleaning power, this series makes short work of tough jobs with 1800 to 3000 PSI high pressure, 300 PSI steam and 4.0 to 6.0 GPM.
| Model |
 |
5403 |
 |
5518 |
 |
5523 |
 |
5530 |
 |
5615 |
 |
5622 |
 |
5630 |
| Flow
Output (GPM) |
|
4 |
|
5 |
|
5 |
|
5 |
|
6 |
|
6 |
|
6 |
| Pressure
Ratings (PSI) |
|
300 |
|
1800 |
|
2300 |
|
3000 |
|
1500 |
|
2200 |
|
3000 |
| Max
Output Temperature (°F) |
|
300° |
|
210° |
|
210° |
|
210° |
|
210° |
|
210° |
|
210° |
| Cleaning
Comparison Index (1) |
|
7750 |
|
20236 |
|
22648 |
|
25866 |
|
21948 |
|
26581 |
|
31039 |
| Motor
Horsepower |
|
2 |
|
6 |
|
8/7.5 |
|
10 |
|
6 |
|
10 |
|
15 |
| Electrical
Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Volt |
|
115 |
|
230 |
|
230 |
|
230 |
|
230 |
|
230 |
|
230 |
| Amp |
|
15 |
|
30/20 |
|
30/25 |
|
30 |
|
30/20 |
|
30 |
|
35 |
| Phase |
|
1 |
|
1
or 3 |
|
1
or 3 |
|
3 |
|
1
or 3 |
|
3 |
|
3 |
| Oil
Fired Burner System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Input
BTU's |
|
726,000 |
|
487,000 |
|
487,000 |
|
487,000 |
|
585,000 |
|
585,000 |
|
585,000 |
| Fuel
Consumption (GPH) (2) |
|
3.11 |
|
2.09 |
|
2.09 |
|
2.09 |
|
2.51 |
|
2.51 |
|
2.51 |
| Burner
Fuel Tank Capacity |
|
25 |
|
25 |
|
25 |
|
25 |
|
25 |
|
25 |
|
25 |
| Stack
Size |
|
10" |
|
10" |
|
10" |
|
10" |
|
10" |
|
10" |
|
10" |
| Gas
Fired Burner System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Input
BTU's |
|
770,000 |
|
545,000 |
|
545,000 |
|
545,000 |
|
670,000 |
|
670,000 |
|
670,000 |
| Fuel
Consumption NG (CFH) (2) |
|
462 |
|
327 |
|
327 |
|
327 |
|
402 |
|
402 |
|
402 |
| Fuel
Consumption LP (LBH) (2) |
|
22.92 |
|
16.23 |
|
16.23 |
|
16.23 |
|
19.95 |
|
19.95 |
|
19.95 |
| LP
Tank Minimum Size |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
| Stack
Size |
|
12" |
|
12" |
|
12" |
|
12" |
|
12" |
|
12" |
|
12" |
| Discharge
Hose |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
|
3/8"
x 50' |
| Approx.
Weight (lbs) |
|
1030 |
|
1005 |
|
1060 |
|
1070 |
|
1060 |
|
1050 |
|
1000 |
| Dimensions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Length |
|
64" |
|
64" |
|
64" |
|
64" |
|
64" |
|
64" |
|
64" |
| Width |
|
28" |
|
28" |
|
28" |
|
28" |
|
28" |
|
28" |
|
28" |
| Height |
|
58" |
|
58" |
|
58" |
|
58" |
|
58" |
|
58" |
|
58" |
|
|
|
6000
1200 to 2500 PSI high pressure, 500 PSI steam and 6.7 to 12.0 GPM. Engineered with the toughest jobs in mind, this series is top of the line in stationary pressure washers.
| Model |
 |
6065 |
 |
6112 |
 |
6122 |
 |
6218 |
 |
6225 |
| Flow
Output (GPM) |
|
6.7 |
|
10 |
|
10 |
|
12 |
|
12 |
| Pressure
Ratings (PSI) |
|
500 |
|
1200 |
|
2220 |
|
1800 |
|
2500 |
| Max
Output Temperature (°F) |
|
300° |
|
210° |
|
210° |
|
210° |
|
210° |
| Cleaning
Comparison Index (1) |
|
16750 |
|
32719 |
|
44301 |
|
48086 |
|
56670 |
| Motor
Horsepower |
|
4 |
|
7.5 |
|
15 |
|
15 |
|
20 |
| Electrical
Requirements |
|
|
|
|
|
|
|
|
|
|
| Volt |
|
230 |
|
230 |
|
230 |
|
230 |
|
230 |
| Amp |
|
22 |
|
30 |
|
42 |
|
42 |
|
54 |
| Phase |
|
1 |
|
3 |
|
3 |
|
3 |
|
3 |
| Oil
Fired Burner System |
|
|
|
|
|
|
|
|
|
|
| Input
BTU's |
|
1,100,000 |
|
920,000 |
|
920,000 |
|
1,100,000 |
|
1,100,000 |
| Fuel
Consumption (GPH) (2) |
|
4.71 |
|
3.94 |
|
3.94 |
|
4.71 |
|
4.71 |
| Burner
Fuel Tank Capacity |
|
41 |
|
41 |
|
41 |
|
41 |
|
41 |
| Stack
Size |
|
16" |
|
16" |
|
16" |
|
16" |
|
16" |
| Gas
Fired Burner System |
|
|
|
|
|
|
|
|
|
|
| Input
BTU's |
|
1,200,000 |
|
1,000,000 |
|
1,000,000 |
|
1,200,000 |
|
1,200,000 |
| Fuel
Consumption NG (CFH) (2) |
|
720 |
|
600 |
|
600 |
|
720 |
|
720 |
| Fuel
Consumption LP (LBH) (2) |
|
35.73 |
|
29.77 |
|
29.77 |
|
35.73 |
|
35.73 |
| LP
Tank Minimum Size |
|
100# |
|
100# |
|
100# |
|
100# |
|
100# |
| Stack
Size |
|
16" |
|
16" |
|
16" |
|
16" |
|
16" |
| Discharge
Hose |
|
1/2"
x 50' |
|
1/2"
x 50' |
|
1/2"
x 50' |
|
1/2"
x 50' |
|
1/2"
x 50' |
| Approx.
Weight (lbs) |
|
2078 |
|
1940 |
|
2115 |
|
2415 |
|
2500 |
| Dimensions |
|
|
|
|
|
|
|
|
|
|
| Length |
|
84" |
|
84" |
|
84" |
|
84" |
|
84" |
| Width |
|
36" |
|
36" |
|
36" |
|
36" |
|
36" |
| Height |
|
84" |
|
84" |
|
84" |
|
84" |
|
84" |
|
(1) Fuel Consumption considers an operating duty cycle of 60%.
(2) Cleaning Comparison Index - This is used in the comparison of pressure washing equipment by taking into account the cleaning effects of water pressure, flow and temperature on cleaning time. The larger the comparison index, the faster the pressure washer will clean. The formula is GPM x 60 x Square Root PSI x [1 + (TEMP -32°) / 310]. |
Copyright © 2012 A-J Sales and Service Co.
A division of Superior Manufacturing & Engineering Corporation
10001 Brighton Rd. Denver, CO 80640
1-800-326-9989
|
|