10001 Brighton Rd.
    Denver, CO 80640
    Phone: (303) 287-0223
    Toll Free: (800) 326-9989
    Fax: (303) 287-6306
    email: info@a-jsales.com

   Pressure Washers 
   Water Heaters
   Steel Eagle
   Pumps/ Accessories
   Request Literature
   Links
   Email Us
   Superior Trailers
   About Us
   Home

Series 3000,5000,6000

Standard Features

  • ETL Listed 

  • Heavy Duty Tubular Steel Frame 

  • Heavy Duty Legs 

  • Durable Hi-gloss Powder Coated Paint 

  • Stainless Steel Compartment Covers 

  • Stainless Steel Combustion Chamber 

  • Heating Coil Constructed of ASTM A53 Schedule 80

  • Steel Pipe 

  • Fuel Efficient Combustion Chamber 

  • Adjustable Temperature Control 

  • High-limit Temperature Control 

  • Waterproof Ignition Transformer 

  • Pressure Relief Valve 

  • Belt Driven Pump 

  • Trigger Gun Control 

  • Stainless Steel Float Tank 

  • Low Water Shut-off Protection 

  • Wire Braid Discharge Hose 

  • Quick Coupled Stainless Steel Nozzles 

  • Automatic Shutdown Timer 

  • Watertight Electrical Panel 

  • Diagnostic Control Monitoring Lights 

  • Calibrated Detergent Mixing Valve 

  • Fuel Water Separator 

  • Electronic Ignition 

  • Hour Meter 

  • Soap Solenoid 

  • Cad Cell Flame Sensor (Oil fired units) 

  • Draft Diverter

 

Control Panel
Easy to understand accessible controls make the AaLadin Pressure Washer simple and safe to operate. The calibrated detergent mixing valve precisely meters detergent allowing for high-pressure soap application
Dual Pump Module
AaLadin's standard features are designed to promote longer life. Quality features such as the belt driving the pump enhance trouble free operation by isolating heat and vibration from the pump and allowing for overload protection. The 6000 series pump module shown utilizes a dual pump configuration to minimize the possibility of down time from the possibility of pump failure

Draft Diverter
Protect your hot water machine from the updrafts that can extinguish the pilot light on gas machines and hinder proper venting of the exhaust with this draft diverter. It fits easily on top of the stack head and is standard equipment on all gas fired machines.
Pump Module Access
Front panel opens and raises up out of the way for easy access to the pump and motor area.

Remote Control Station
The remote operation station allows the user the ability to operate the panel controls away from the unit. All remote control stations are 24 volts.
Easy Burner Accessibility
End panel door opens allowing spacious easy access to burner and gas valve.

Heat Chamber - AaLadin Exclusive
The AaLadin heating chamber construction provides long life and fuel efficiencies unsurpassed in the industry. Coils are made of high test ASTM A53 steel pipe wound on a spiral helix with special hot gas baffling. We blanket insulate the entire chamber with a highly efficient insulation blanket with low heat storage and high heat reflectance.Our burner system has a worldwide reputation for superior performance and reliability.
ETL Listed
All models in standard configuration are ETL Listed to ensure safety and the capability of meeting electrical code requirements. (Steam Combination units not ETL Listed)

3000
With 1600 to 3000 PSI high pressure, 300 PSI steam, and 3.0 to 5.0 GPM these stationary pressure washers have exceptional power to get the job done fast. 
Model 3303 3416 3423 3430 3518 3523 3530
Flow Output (GPM)   3   4   4   4   5   5   5
Pressure Ratings (PSI)   300   1600   2300   3000   1800   2300   3000
Max Output Temperature (F)   300   210   210   210   210   210   210
Cleaning Comparison Index (1)   5812   15112   18118   20693   20036   22648   25866
Motor Horsepower   .75   4   6   8/7.5   6   8/7.5   10
Electrical Requirements                            
Volt   115   230   230   230   230   230   230
Amp   10   20/15   20/15   30/25   30/20   30/25   30
Phase   1   1 or 3   1 or 3   1 or 3   1 or 3   1 or 3   3
Oil Fired Burner System                            
Input BTU's   420,000   350,000   350,000   350,000   420,000   420,000   420,000
Fuel Consumption (GPH) (2)   1.8   1.5   1.5   1.5   1.8   1.8   1.8
Burner Fuel Tank Capacity   15.5   15.5   15.5   15.5   15.5   15.5   15.5
Stack Size   8"   8"   8"   8"   8"   8"   8"
Gas Fired Burner System                            
Input BTU's   440,000   400,000   400,000   400,000   440,000   440,000   440,000
Fuel Consumption NG (CFH) (2)   264   240   240   240   264   264   264
Fuel Consumption LP (LBH) (2)   13.1   11.91   11.91   11.91   13.1   13.1   13.1
LP Tank Minimum Size   100#   100#   100#   100#   100#   100#   100#
Stack Size   10"   10"   10"   10"   10"   10"   10"
Discharge Hose   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'
Approx. Weight (lbs)   730   728   776   794   824   848   848
Dimensions                            
Length   56"   56"   56"   56"   56"   56"   56"
Width   24"   24"   24"   24"   24"   24"   24"
Height   55"   55"   55"   55"   55"   55"   55"

5000
For extra cleaning power, this series makes short work of tough jobs with 1800 to 3000 PSI high pressure, 300 PSI steam and 4.0 to 6.0 GPM.
Model 5403 5518 5523 5530 5615 5622 5630
Flow Output (GPM)   4   5   5   5   6   6   6
Pressure Ratings (PSI)   300   1800   2300   3000   1500   2200   3000
Max Output Temperature (F)   300   210   210   210   210   210   210
Cleaning Comparison Index (1)   7750   20236   22648   25866   21948   26581   31039
Motor Horsepower   2   6   8/7.5   10   6   10   15
Electrical Requirements                            
Volt   115   230   230   230   230   230   230
Amp   15   30/20   30/25   30   30/20   30   35
Phase   1   1 or 3   1 or 3   3   1 or 3   3   3
Oil Fired Burner System                            
Input BTU's   726,000   487,000   487,000   487,000   585,000   585,000   585,000
Fuel Consumption (GPH) (2)   3.11   2.09   2.09   2.09   2.51   2.51   2.51
Burner Fuel Tank Capacity   25   25   25   25   25   25   25
Stack Size   10"   10"   10"   10"   10"   10"   10"
Gas Fired Burner System                            
Input BTU's   770,000   545,000   545,000   545,000   670,000   670,000   670,000
Fuel Consumption NG (CFH) (2)   462   327   327   327   402   402   402
Fuel Consumption LP (LBH) (2)   22.92   16.23   16.23   16.23   19.95   19.95   19.95
LP Tank Minimum Size   100#   100#   100#   100#   100#   100#   100#
Stack Size   12"   12"   12"   12"   12"   12"   12"
Discharge Hose   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'   3/8" x 50'
Approx. Weight (lbs)   1030   1005   1060   1070   1060   1050   1000
Dimensions                            
Length   64"   64"   64"   64"   64"   64"   64"
Width   28"   28"   28"   28"   28"   28"   28"
Height   58"   58"   58"   58"   58"   58"   58"

6000
1200 to 2500 PSI high pressure, 500 PSI steam and 6.7 to 12.0 GPM. Engineered with the toughest jobs in mind, this series is top of the line in stationary pressure washers.
Model 6065 6112 6122 6218 6225
Flow Output (GPM)   6.7   10   10   12   12
Pressure Ratings (PSI)   500   1200   2220   1800   2500
Max Output Temperature (F)   300   210   210   210   210
Cleaning Comparison Index (1)   16750   32719   44301   48086   56670
Motor Horsepower   4   7.5   15   15   20
Electrical Requirements                    
Volt   230   230   230   230   230
Amp   22   30   42   42   54
Phase   1   3   3   3   3
Oil Fired Burner System                    
Input BTU's   1,100,000   920,000   920,000   1,100,000   1,100,000
Fuel Consumption (GPH) (2)   4.71   3.94   3.94   4.71   4.71
Burner Fuel Tank Capacity   41   41   41   41   41
Stack Size   16"   16"   16"   16"   16"
Gas Fired Burner System                    
Input BTU's   1,200,000   1,000,000   1,000,000   1,200,000   1,200,000
Fuel Consumption NG (CFH) (2)   720   600   600   720   720
Fuel Consumption LP (LBH) (2)   35.73   29.77   29.77   35.73   35.73
LP Tank Minimum Size   100#   100#   100#   100#   100#
Stack Size   16"   16"   16"   16"   16"
Discharge Hose   1/2" x 50'   1/2" x 50'   1/2" x 50'   1/2" x 50'   1/2" x 50'
Approx. Weight (lbs)   2078   1940   2115   2415   2500
Dimensions                    
Length   84"   84"   84"   84"   84"
Width   36"   36"   36"   36"   36"
Height   84"   84"   84"   84"   84"


(1) Fuel Consumption considers an operating duty cycle of 60%.
(2) Cleaning Comparison Index - This is used in the comparison of pressure washing equipment by taking into account the cleaning effects of water pressure, flow and temperature on cleaning time. The larger the comparison index, the faster the pressure washer will clean. The formula is GPM x 60 x Square Root PSI x [1 + (TEMP -32) / 310]. 

  

Copyright 2015 A-J Sales and Service Co.
A division of Superior Manufacturing & Engineering Corporation
10001 Brighton Rd.   Denver, CO 80640