Optional Galvanized Frame with Optional Skid Mount
|
This equipment meets the U.S. and Canadian National Electric Codes and complies
with OSHA Regulation 1910.303(a). To operate,
just connect the cleaner to your plant 3-phase electrical source and water supply. |
Sioux®
All-Electric Cleaners Siouxs
All-electric steam cleaners, pressure washers and combination cleaners are ideal for
indoor/outdoor use, and in potentially hazardous environments. Unlike fuel-fired machines,
Siouxs All-electric line produces no fumes, exhaust or open flames.
This makes our cleaners well suited for indoor applications
and enclosed spaces where air quality is a concern. Siouxs entire line of
All-Electric steam cleaners are ETL listed, providing third-party certification to UL-1776
standard, "High Pressure Cleaning Machines;" and the Canadian Standards
Association CSA C-22.2 No. 68-92 standard, "Motor-Operated Appliances,
Commercial." |
Explosion-Proof Units |
All models (steam cleaners, pressure washers, and combination cleaners) can be
built to explosion-proof specifications. Explosion-proof units are designed for use in
hazardous and potentially volatile environments where safety is critical. In addition to meeting the All-Electric standards above, Sioux
explosion-proof models are also ETL certified to UL-1203, "Explosion-Proof and Dust
Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations," and
Canadian CSA C-22.2 No. 30-92. |

|
Sioux
Explosion-Proof Cleaners are approved for use in the following classifications: Class I Flammable Gases or Vapors
Division 1 Concentrations of Gases or Vapors
exist under normal operating conditions.
Division 2 Concentration of Gases or Vapors are normally prevented.
Group C Atmospheres such as Cyclopropane, Ethyl Ether, Ethylene, or gases
or vapors equivalent in hazard.
Note: Equipment must be special ordered with Group C motor.
Group D Atmospheres such as Acetone, Alcohol, Ammonia, Benzene, Benzol,
Butane, Gasoline, Hexane, Lacquer solvents, Naphtha, Natural Gas, Propane, or gases or
vapors equivalent in hazard.
All models (steam cleaners, hot pressure washers, and combination units) with the
explosion-proof option meet Class I, Division 1 and 2, Group C and D.
Class II Explosive Dusts
Division 1 Explosive dusts exist under
normal operating conditions.
Division 2 Explosive dusts are normally prevented.
Group E Atmospheres containing metal dust and other combustible dusts
including aluminum, magnesium, and their commercial alloys, and other metals of similarly
hazardous conditions.
Note: Not appropriate for atmospheres containing Uranium,
Thorium, or Zirconium dust.
Group F Carbon black, charcoal, coal, or coke and similar materials.
Only hot pressure washers with the explosion-proof option will meet requirement for
Class II, Division 1 and 2, Group E and F.